Breaker/Hammer Storage

Short Term Storage

  • Lay the breaker on wooden blocks. Remove the pins to disconnect the breaker from the boom.
  • Remove the tool and ensure the retaining pins, bushings and piston bottom are well greased.
  • Reinstall the tool.
  • Cover with a tarp.

Long-Term Storage - Preferred Method

  • Remove the tool. Liberally grease inside the front head, piston bottom, and retaining pins.
  • Release the cushion chamber gas pressure.
  • Push the piston up inside the breaker.
  • Reinstall the tool.
  • Cover with a tarp.

Long-Term Storage - Alternate Method

  • Store breaker upright in a safety stand.
  • DO NOT release the cushion chamber gas pressure.
  • Allow the breaker weight to push the tool up into the breaker.